Model CS350M single-channel potentiostat galvanostat consists of a DDS arbitrary function generator, a potentiostat/galvanostat and an FRA. With the help of built-in dual 24-bit Delta-sigma AD converters, it achieves excellent stability and high potential (1mV) and current(1pA) resolutions. CS350M has been widely applied in corrosion, energy, material and analysis electrochemistry. In addition, via current booster. CS350M can increase its output current up to 20A/40A/100A.\
Specifications
Specifications | |
Support 2-, 3- or 4-electrode system | Potential and current range: Automatic |
Potential control range: ±10V(can be customized to ±12V) | Current control range: ±2A |
Potential control accuracy: 0.1%×full range±1mV | Current control accuracy: 0.1%×full range |
Potential resolution: 10μV (ssshhh100Hz),3μV (<10Hz) | Current sensitivity:1pA |
Rise time: <1μS (<10mA), <10μS (<2A) | Reference electrode input impedance:1012Ω||20pF |
Current range: 2nA~2A, 10 ranges | Compliance voltage: ±21V |
Maximum current output: 2A | CV and LSV scan rate: 0.001mV~10,000V/s |
CA and CC pulse width: 0.0001~65,000s | Current increment during scan: 1mA@1A/ms |
Potential increment during scan: 0.076mV@1V/ms | SWV frequency: 0.001~100 kHz |
DPV and NPV pulse width: 0.0001~1000s | AD data acquisition:16bit@1 MHz,20bit@1 kHz |
DA Resolution:16bit, setup time:1μs | Minimum potential increment in CV: 0.075mV |
IMP frequency: 10μHz~1MHz | Low-pass filters: covering 8-decade |
Operating System: Windows 10/11 | Interface: USB 2.0 |
Weight / Measurements: 6.5kg, 36.5 x 30.5 x16 cm |
product picture
single-channel potentiostat galvanostat
single-channel potentiostat galvanostat consists of a DDS arbitrary function generator, a potentiostat/galvanostat and an FRA. With the help of built-in dual 24-bit Delta-sigma AD converters, it achieves excellent stability and high potential (1mV) and current(1pA) resolutions.
Lab Single-channel potentiostat Galvanostat
battery potentiostat galvanostat The main function is to accurately control and measure the potential or current in electrochemical experiments. In electrochemical research, specific potential or current can be set to achieve the regulation of the electrode reaction, so as to study the electrode process dynamics, electrochemical reaction mechanism, electrochemical performance testing of materials, such as battery performance assessment, plating process optimization, etc., is an important instrument in the electrochemical laboratory.
Company Profile
Xiamen AOT battery equipment Technology was set up as a manufacturer in 2006. We have total manufacturing facilities of around 4, 000 square meters and more than 65 staff. Owning a group of experienced engineers and staffs, we can bring you not only reliable products and technology, but also excellent services and real value you will expect and enjoy. AOT Battery has been focused on product development and operations of lithium battery and its surrounding, we supply full kinds of lithium-ion battery equipment, lab battery raw materials and lithium-ion battery research and development technology.
Exhibition
AOT Lithium Battery Equipment exhibition provides exhibitors and visitors with a comprehensive platform for display, exchange, cooperation and trade. By participating in the exhibition, enterprises can understand the industry dynamics, expand market channels, enhance brand image and promote technological innovation and industrial upgrading.
Certificate
Cooperative partner
FAQ
1、What is single-channel potentiostat galvanostat ?
battery potentiostat galvanostat The main function is to accurately control and measure the potential or current in electrochemical experiments. In electrochemical research, specific potential or current can be set to achieve the regulation of the electrode reaction, so as to study the electrode process dynamics, electrochemical reaction mechanism, electrochemical performance testing of materials, such as battery performance assessment, plating process optimization, etc., is an important instrument in the electrochemical laboratory.
2、battery single-channel potentiostat galvanostat of Galvanostat
First, connect the battery to the instrument to ensure that the wiring is properly connected. Then turn on the instrument power supply, set the experimental parameters on the operation interface, such as target potential, current value, scanning rate, etc. After the setting, start the experiment, and the instrument begins to charge and discharge the battery according to the set parameters. During the experiment, the data were observed and recorded in real time. After the end of the experiment, turn off the power and sort out the instrument and related lines.
3、battery potentiostat Influencing factors of Galvanostat
The accuracy and stability of the instrument itself are very important, low accuracy and poor stability will make the measurement results biased. In terms of the battery, its type, state, internal resistance and temperature will affect the measurement data. The temperature and humidity in the external environment will change the battery performance and the working state of the instrument; Electromagnetic interference can also interfere with the signal transmission of the instrument, causing errors in the measurement results. During operation, it is also necessary to pay attention to the degree of operation specification of personnel.